Contact Us

Tel:+86-573-86579525

Fax:+86-573-86579525

Mob:+86-18768335213

E-mail: info@mes-heatpump.com

Add: West of Dayang Bridge, North of Huhang Road, Fouth Group of Dongfang Villiage, Ganpu Town, Haiyan County, Jiaxing,  Zhejiang, China

Hot Tags: Residential Heat PumpsCommercial Heat PumpsSwimming Pool Heat PumpsHeat Pump

Commercial Air Source Heat Pumps For Lowest Ambient Temperature -15℃ Area

Commercial air source heat pumps for lowest ambient temperature -15℃ area

Inquiry

  • Product Details

Commercial air source heat pumps for waraming forlowest ambient temperature -15℃ area 


This is air source heat pumps for commercial building warming, it is the normal one which can work in lowest ambient temperature -15℃, the highest capacity can reach 145KW and the control system has RS485 function so that more heat pumps can work together.

We have great experience for all kinds of heat pumps, with the professional equipment, sales, engineers and workers, we will supply the best products for you.


Product Info.

Compressor

Copeland scroll or Panasonic scroll

Capacity

9KW,15KW,20KW,30KW,40KW,55KW,60KW,72KW, 90KW, 108KW,145KW

Refrigerant

R410A

Condenser

"ND" Shell & Coil heat exchanger

Evaporator

Finned tube heat exchanger(high quality, with stainless steel 304 of frame)

AC contactor & Relay

Schneider

Electronic expansion valve

Japan Saginomiya or World No.1 Sanhua

Reversing valve

World No.1 Sanhua

Controller

LCD

Package

Wooden case or Carton

Fasteners

Stainless steel 304


Additional Info. 

Delivery time

25 days after order confirmed

Warranty time

24 months after shipment

Payment term

T/T or L/C at sight

Production capacity

400 units per month

Brand

MES or OEM

    

Parameters 

Warmer-CV series(Commercial Air source heat pump for House heating & Hot water)







WM-CV-1609

WM9s-CV5WM15s-CV5WM9-CV5WM15-CV5WM20-CV5WM30-CV10WM40-CV10WM55-CV10WM60-CV20WM72-CV20WM90-CV20WM108-CV20WM145-CV40

Rated house heating 

capacity

kW91591520304055607290108145

Rated input power for 

house heating

kW2.744.572.84.576.279.0612.1216.6218.422.0927.6133.1344.48

Rated input current for 

house heating

A12.220.335.38.6411.8517.1322.9131.434.7941.7452.1862.6184.06

Heating performance 

coefficient (COP)

/3.283.283.213.283.193.313.33.313.263.263.263.263.26

Hot water heating 

capacity

kW12191219253550657585105125165

Input power for hot 

water heating

kW2.724.292.714.285.647.9211.3614.7316.8919.1923.728.2837.33

Input current for hot 

water heating

A11.8818.734.947.7910.2714.4120.6827.8330.7434.9243.1451.4767.94

Hot water performance 

coefficient(COP)

/4.414.434.424.444.434.424.44.414.444.434.434.424.42
Maximum input powerkW3.545.583.535.567.3410.2914.7718.8521.9624.9430.8136.7648.53
Maximum input currentA15.4524.356.6710.5113.8719.4627.9235.841.547.1458.2469.4991.72
Power supply1N 220V/50Hz

3N 380V/50Hz(Special power supply for option)

(Special power 

supply for option)

CompressorTypeHermetic scroll type
Start mode

Directly start

(Soft start for option)

QuantitySet1111122222334
Water SideHeat exchangerShell & coil(tube) heat exchanger
Water flowm3/h2.13.32.13.34.368.611.212.914.618.121.528.4

Water pressure 

drop

kPa≤45≤53≤45≤53≤55<60<60<60<65<68<70<70<75
Connection sizeDNDN25DN25DN25DN25DN25DN32DN32DN50DN50DN50DN50DN65DN80
Air SideExchangerFinned tube heat exchanger
Rated Air flowm3/h350063203500632075001250014800148002600026000390003900052000

Rated output 

power 

of fan motor

W12025012025037055075075011001100150015002200
Protections1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection, etc..
RefrigerantThrottle typeElectronic expansion valve
TypeR410a
Quantitykg1.92.81.92.84.12.8×24.1×25.2×23.2×47.6×26.2×37.6×37.6×4
NoiseDB(A)≤55≤63≤55≤63≤65≤65≤66≤68≤70≤72≤73≤75≤78
Dimensionmm710x710x1100990x990x18001000x2050x18502000x2050x
1850

Wooden case package 

dimensions(L*W*H)

mm766x766x11461046x1046x19681056x2106x20182056x2106x
2018
Net weightkg1081351081351653404004856056608358401230
Gross weightkg1231501231501803704305156406958708751265
1. Heating standard condition: Dry-bulb temperature 7℃, wet bulb temperature 6℃;  Cold water inlet temperature 40℃, Hot water outlet temperature 45℃;
2. Hot water standard condition: Initial water temperature 15 ℃, the setting  water temperature 55 ℃; Dry-bulb temperature 20℃, wet bulb temperature 15℃.
The above parameters based on Refrigearnt R410A, for parameters based on other refrigerants please contact us.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.


MES, one of the professional manufacturers and suppliers of commercial air source heat pumps for lowest ambient temperature -15℃ area in China, has been developing and manufacturing heat pumps for over 10 years and become one of the famous such brands. In order to make customers 100% satisfied, we also offer installation service. Now, don't hesitate to buy high quality commercial air source heat pumps for lowest ambient temperature -15℃ area made in China at competitive price with our factory.

Related Products