Commercial Water Source Heat Pumps For Cooling And Heating

Commercial water source heat pumps for cooling and heating

Inquiry

  • Product Details

Commercial water source heat pumps for cooling and heating 


This is water source heat pumps commercial use for cooling and heating, it is usually installed in area where weather very cold in winter, and in summer it can also supply chilled water for cooling.

We only use the best quality and famous brand parts for assembling and all the testing for the heat pump parts and heat pump units will be finished by expert workers and engineers with professional equipment.


Product Info.

Compressor

Copeland scroll or Panasonic scroll

Capacity

11KW,17KW,24KW,34KW,48KW,68KW,80KW,
     120KW,160KW

Refrigerant

R410A

Condenser

"ND" shell and tube heat exchanger

Evaporator

Shell & tube, tube in tube or plate type heat exchanger

AC contactor & Relay

Schneider

Electronic expansion valve

Japan Saginomiya or World No.1 Sanhua

Controller

LCD

Package

Wooden case or Carton

Fasteners

Stainless steel 304


Additional Info. 

Delivery time

25 days after order confirmed

Warranty time

24 months after shipment

Payment term

T/T or L/C at sight

Production capacity

400 units per month

Brand

MES or OEM


Parameters 

Cooler-CW (Commercial Water 

source heat pump for 

cooling & heating)

 CL-CW-1609











CL11s-CW5CL17s-CW5CL11-CW5CL17-CW5CL24-CW5CL34-CW10CL48-CW10CL68-CW20CL80-CW20CL120-CW20CL160-CW20
Underground water open loopRated cooling capacityKW111711172434486880120160

Rated input power 

for cooling

KW2.153.342.113.24.726.539.1813.1815.7223.3531.56

Rated input current 

for cooling

A9.5514.843.986.048.9112.3317.3524.9129.7144.1259.64

Cooling performance 

coefficient (EER)

/5.125.095.225.325.095.215.235.165.095.145.07
Rated heating capacityKW9.5169.5162232456575115150

Rated input power for 

heating

KW2.594.382.594.316.098.8612.3318.0121.0132.3941.78

Rated input current for 

heating

A12.3320.874.898.1511.5216.7523.334.0339.7161.2378.97

Heating performance 

coefficient (COP)

/3.673.653.673.713.613.613.653.613.573.553.59

Application side heat 

exchanger water flow

M3/h1.892.921.892.924.135.858.2611.713.7620.6427.52

Heat source side heat 

exchanger water flow

M3/h1.031.591.031.592.253.194.56.387.5111.2615.01
Ground source closed loopRated cooling capacityKW101610162232466476114150

Rated input power for 

cooling

KW1.963.171.953.134.386.178.8312.4814.922.2729.64

Rated input current for 

cooling

A8.714.113.685.918.2811.6516.6923.5828.1642.0856.03

Cooling performance 

coefficient (EER)

/5.115.045.135.125.025.195.215.135.15.125.06
Rated heating capacityKW812812162433485786115

Rated input power for

 heating

KW3.074.433.044.585.999.212.618.3922.0132.9543.73

Rated input current 

for heating

A13.2719.175.668.5211.1517.123.4334.2140.9361.2981.33

Heating performance 

coefficient (COP)

/2.612.712.632.622.672.612.622.612.592.612.63

Application side heat 

exchanger water flow

M3/h1.382.061.382.062.754.135.688.269.814.7919.78

Heat source side heat 

exchanger water flow

M3/h1.722.581.722.583.445.167.110.3212.2618.4924.73
Power supply1N 220V/50Hz (Special power supply for option)3N 380V/50Hz(Special power supply for option)
CompressorTypeHermetic scroll type
QuantityPCS11111222234
Heat source side heat exchangerTypeShell & coil(tube) heat exchanger
Connection sizeDNDN20DN25DN25DN25DN25DN32DN32DN50DN65DN65DN80
Application side heat exchangerTypeShell & coil(tube) heat exchanger
Connection sizeDNDN20DN25DN25DN25DN25DN32DN32DN50DN65DN65DN80
Protections1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.
RefrigerantTypeR410A
QuantityKG2.63.32.63.34.23.3x24.2x26.6x27.6x27.6x37.6x4
Dimensionmm790x415x590790x710x9502000x1000x1600
Wooden case package dimensions(L*W*H)mm836x461x752836x756x11122056x1056x1768
Net weightKG6895659513519532079588511801210
Gross weightKG781057510514521534083092012151245
NoiseDB(A)≤53≤55≤55≤55≤58≤58≤62≤65≤70≤75≤75
Note:
1. Underground water open loop type cooling standard condition: application side water input/output temperature 12℃/7℃; source side water input/output temperature 18℃/29℃. Underground water open loop type heating standard condition: application side water input/output temperature 40℃/45℃; source side water input/output temperature 15℃/-a.

2. Ground source closed loop type cooling standard condition: application side water input/output temperature 12℃/7℃; source side water input/output temperature 25℃/30℃ 

Ground source closed loop type heating standard condition: application side water input/output temperature 40℃/45℃ ; source side water input/output temperature 5℃/-a.

3. "-a " means the water flow under cooling standard condition.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret.


MES, one of the professional manufacturers and suppliers of commercial water source heat pumps for cooling and heating in China, has been developing and manufacturing heat pumps for over 10 years and become one of the famous such brands. In order to make customers 100% satisfied, we also offer installation service. Now, don't hesitate to buy high quality commercial water source heat pumps for cooling and heating made in China at competitive price with our factory.